CALIBRATE command captures per-subcarrier CSI amplitudes over a timed window and stores the averaged baseline in NVS. PRESENCE command enables real-time scoring via normalized Euclidean distance against the baseline, with rolling window averaging and 10s holdoff on state transitions. New commands: CALIBRATE [3-60|STATUS|CLEAR], PRESENCE [ON|OFF|THRESHOLD] New NVS keys: bl_amps (blob), bl_nsub, presence, pr_thresh New STATUS fields: presence=, pr_score= New events: calibrate=done, presence=0|1